Quick summary: LUMINOS DRF MAX, UROSKOP OMNIA MAX, MULTITOM RAX. Date: 2022-04-13.
LUMINOS DRF MAX, UROSKOP OMNIA MAX, MULTITOM RAX
2022-04-13
Recommended action: compare your product with the official notice and follow the instructions published by the official source.
Recall details
Quick summary: LUMINOS DRF MAX, UROSKOP OMNIA MAX, MULTITOM RAX. Date: 2022-04-13.
Affected product details
Structured information extracted from the official recall notice. Confirm the identifiers and instructions in the original notice.
Affected products
Issue
Siemens Healthcare will be distributing new operator's manuals to affected customers which are needed for the upcoming software upgrade to VF11. 5 cautions were added to the manual. Caution 1 (added two sentences to already existing caution): cause: Patient falls during standing 3d Remedy: Always use the 3d ortho stand for standing 3d studies. Aid patient in climbing onto the 3d ortho stand. Make sure that the patient is stable enough to stand for the entire examination Caution 2 cause: Operator or patient trips over the foot switch cable or the foot switch itself Remedy: position the foot switch and the associated cable on the floor so that nobody trips. Caution 3: cause: the detector holder is not securely fastened Remedy: make sure the detector holder is securely fastened Caution 4: cause: riding on wheeled accessories Remedy: Do not ride or allow anyone else to stand, sit or ride on wheeled accessories while they are being rolled. Caution 5: cause: unauthorized access to the system Remedy: the hospital is responsible for network security at the site. Set up firewalls and user account password protections. Do not allow users to change configuration files. Update virus protection software as required. Siemens Healthcare will be distributing new operator's manuals to affected customers which are needed for the upcoming software upgrade to VF11. Caution: cause: patient cannot maintain position or becomes unconscious Remedy: check that the patient is physically able to hold the examination position, especially when standing. Choose a different position or use positioning aids for immobilizing weak or very unstable patients. Caution cause: unauthorized access to the system remedy: The hospital is responsible for network security at the site. set up firewalls. Siemens Healthcare will be distributing new operator's manuals to affected customers which are needed for the upcoming software upgrade to VF11. This update delivers a new manual to customers to be able to use the upcoming software version VF11. A caution was added to the manual to prevent unauthorized access to the system. Recall start date: Apr 5, 2022
What you should do
- Contact the manufacturer if you require additional information.
Additional official information
Contains information licensed under the Open Government Licence – Canada. SafetyPulse is independent of the Government of Canada.
Frequently asked questions
Answers based on the official recall notice.
Product images
Official product images from Health Canada.
Starting...
Explore more
Related recalls
Similar recalls and safety notices.