Public recall detail

ITS4850A IntelliVue Telemetry System-Monitor

2023-06-14

medium
Recall Safety notice
Quick summary

Quick summary: ITS4850A IntelliVue Telemetry System-Monitor. Date: 2023-06-14.

Recommended action

Recommended action: compare your product with the official notice and follow the instructions published by the official source.

Recall details

Quick summary: ITS4850A IntelliVue Telemetry System-Monitor. Date: 2023-06-14.

Official details

Affected product details

Structured information extracted from the official recall notice. Confirm the identifiers and instructions in the original notice.

BrandPHILIPS MEDICAL SYSTEMS
ProductITS4850A IntelliVue Telemetry System-Monitor
IssueMedical devices - Performance
Recall classType II
IdentificationRA-73818

Affected products

ProductITS4850A IntelliVue Telemetry System-Monitor
LotNot applicable.
ModelMX40
Serial numberNot applicable.
DescriptionITS4850A IntelliVue Telemetry System-Monitor

Issue

When the MX40 is in standby mode for an extended period without patient surveillance no monitoring or alarming is available because alarms, as designed, cannot be triggered when the MX40 is in standby mode. When users place the MX40 device in standby mode, there are 2 possible outcomes: 1) If a timed duration (i.e., 10 minutes to 4 hours) is used for standby, the MX40 will automatically resume monitoring and end standby mode at the end of the time period; or 2) If infinite duration is used for standby mode, the device will not resume monitoring until standby is manually ended by the user or a "tele battery low" inop condition occurs. While the MX40 device is in standby, physiological monitoring and alarming is stopped. Therefore, there may be a hazardous situation present if a user places an MX40 in standby longer than intended for completion of a patient procedure or test if the device is not taken out of standby. Recall start date: June 2, 2023

What you should do

  • Contact the manufacturer if you require additional information.
Additional official information
AudienceHealthcare
CategoryHealth products - Medical devices - Cardiovascular
CompaniesPhilips Medical Systems 3000 Minuteman Road, Andover, Massachusetts, United States, 01810
Published byHealth Canada
Recall classType II
Alert / recall typeHealth product recall
Identification numberRA-73818
Background{}
CompaniesPhilips Medical Systems 3000 Minuteman Road, Andover, Massachusetts, United States, 01810
AudiencesHealthcare
Source updated2023-06-14