BD Alaris Gateway Workstation

2023-07-21

medium
Recall Safety notice
Quick summary

Quick summary: BD Alaris Gateway Workstation. Date: 2023-07-21.

Recommended action

Recommended action: compare your product with the official notice and follow the instructions published by the official source.

Recall details

Quick summary: BD Alaris Gateway Workstation. Date: 2023-07-21.

Official details

Affected product details

Structured information extracted from the official recall notice. Confirm the identifiers and instructions in the original notice.

BrandBD Switzerland Sarl
ProductBD Alaris Gateway Workstation
IssueMedical devices - Performance
Recall classType II
IdentificationRA-73969

Affected products

ProductBD Alaris Gateway Workstation
LotAll lots.
Model80203UNS02-30 80203UNS02-34 80203UNS02-54 80203UNS02-74 80203UNS03-34 80203UNS03-52 80203UNS03-53 80300UNS02-53 80300UNS02-72 80203UNS01-32 80203UNS01-53 80203UNS02-50 80203UNS02-72 80203UNS02-73 80300UNS02-32 80203UNS01-235 80203UNS01-72 80203UNS02-235 80203UNS03-30 80203UNS03-32 80300UNS02-235 80203UNS01-34 80203UNS01-50 80203UNS01-92 80203UNS02-33 80203UNS03-54 80300UNS02-34
Serial numberAll lots.
DescriptionBD Alaris Gateway Workstation
ProductBD Alaris Gateway Workstation
LotAll lots.
Model80203UNS01-30 80203UNS01-33 80203UNS01-73 80203UNS02-52 80203UNS02-92 80203UNS03-74 80203UNS01-52 80203UNS01-70 80203UNS02-035 80203UNS02-53 80203UNS03-72 80300UNS02-73 80203UNS01-54 80203UNS03-33 80203UNS03-50 80300UNS02-50 80300UNS02-54 80300UNS02-70 80300UNS02-74 80300UNS02-92 80203UNS01-74 80203UNS02-32 80203UNS02-70 80203UNS03-70 80203UNS03-73 80300UNS02-035 80300UNS02-33 80300UNS02-52
Serial numberAll lots.
DescriptionBD Alaris Gateway Workstation

Issue

BD is issuing a recall because product testing demonstrated that the BD Alaris™ Gateway Workstation can no longer claim protection against fluid ingress according to international standard, ip22/ipx1. Therefore, BD is providing a notice to affected customers to re-enforce the use of the existing directions for use (DFU) and technical service manual (TSM) to minimize potential fluid ingress. During the evaluation of the AGW, the unit was subject to water as per iec 60529 test requirements for ipx2. As part of clause 11.6.5 from iec 60601-1, after the tests of iec 60529, the device is to show no signs of bridging of insulation that is likely to result in the loss of basic safety or essential performance in normal condition or in combination with a single fault condition. The single fault condition identified prior to starting the test was a failure of the pump detection circuit, leading to voltage being on the iec outlet on the tile, when no pump is present. This single fault condition in combination with water being present on the iec c13 outlet, where water could conduct a path from the live terminal to an operator, resulted in ul deeming the test a failure. The DFU contains a claim for ip22 protection. Recall start date: July 7, 2023

What you should do

  • Review notice & distribute to users, follow instructions provided, complete/ return response form.
Additional official information
AudienceHealthcare
CategoryHealth products - Medical devices - Gastroenterology and urology
CompaniesBd Switzerland Sarl Route De Crassier 17, Eysins, Switzerland, 1262
Published byHealth Canada
Recall classType II
Alert / recall typeHealth product recall
Identification numberRA-73969
Background{}
CompaniesBd Switzerland Sarl Route De Crassier 17, Eysins, Switzerland, 1262
AudiencesHealthcare
Source updated2023-07-21