Public recall detail

Azurion 3 and 7

2024-08-14

medium
Recall Safety notice
Quick summary

Quick summary: Azurion 3 and 7. Date: 2024-08-14.

Recommended action

Recommended action: compare your product with the official notice and follow the instructions published by the official source.

Recall details

Quick summary: Azurion 3 and 7. Date: 2024-08-14.

Official details

Affected product details

Structured information extracted from the official recall notice. Confirm the identifiers and instructions in the original notice.

BrandPHILIPS MEDICAL SYSTEMS NEDERLAND B.V.
ProductAzurion 3 and 7
IssueMedical devices - Performance
Recall classType II
IdentificationRA-75918

Affected products

ProductAzurion 3 M15
LotNot applicable.
Model722 064
Serial numberNot applicable.
DescriptionAzurion 3 M15
ProductAzurion 7 M12
LotNot applicable.
Model722 078
Serial numberNot applicable.
DescriptionAzurion 7 M12
ProductAzurion 3 M12
LotNot applicable.
Model722 063
Serial numberNot applicable.
DescriptionAzurion 3 M12
ProductAzurion 7 B20
LotNot applicable.
Model722 068
Serial numberNot applicable.
DescriptionAzurion 7 B20
ProductAzurion 7 M20
LotNot applicable.
Model722 079
Serial numberNot applicable.
DescriptionAzurion 7 M20
ProductAzurion 7 B12
LotNot applicable.
Model722 067
Serial numberNot applicable.
DescriptionAzurion 7 B12

Issue

Philips has identified two issues in software version R1.X of the Philips Azurion system that may affect: a) Management of the system log trace files: The mechanism that is present in the system to manage the number and size of the system log trace files does not function properly, as a result of which the log trace files related to remote connection logging may occupy the full hard disk capacity of the Philips Azurion R1.X system. When the full disk capacity is reached, imaging (X-ray) functionality will cease to be available without an advance warning to the user. A restart of the system will not resolve the issue. Note: This issue only impacts the Philips Azurion R1.X systems that are currently connected to Philips remote service or that were connected in the past. b) Time to perform a cold restart: A cold restart of the Philips Azurion R1.X system may take up to 6 minutes as stated in the instructions for use of the system (section 4.2). This time includes the time required for the system to shut down and the system to start up. However, there are instances where the shutdown of the system may be prolonged (with up to 4 minutes) resulting in the cold restart taking longer (up to 10 minutes in total). Recall Start Date: July 17, 2024

What you should do

  • ​​​​​​Contact the manufacturer if you require additional information.
Additional official information
AudienceHealthcare
CategoryHealth products - Medical devices - Radiology
CompaniesPhilips Medical Systems Nederland B.V. Veenpluis 6, Best, Netherlands, 5684 PC
Published byHealth Canada
Recall classType II
Alert / recall typeHealth product recall
Identification numberRA-75918
Background{}
CompaniesPhilips Medical Systems Nederland B.V. Veenpluis 6, Best, Netherlands, 5684 PC
AudiencesHealthcare
Source updated2024-08-14